???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: https://tede.inatel.br:8080/tede/handle/tede/136
Full metadata record
DC FieldValueLanguage
dc.creatorMagalhães, Gilberto Vilas Boas-
dc.creator.Latteshttp://lattes.cnpq.br/1189415245115458por
dc.contributor.advisor1Ribeiro, José Antônio Justino-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/9987344139958522por
dc.contributor.referee1Ribeiro, José Antônio Justino-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/9987344139958522por
dc.contributor.referee2Guimarães, Dayan Adionel-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/2503439503631682por
dc.contributor.referee3Portelinha, Francisco Martins-
dc.contributor.referee3Latteshttp://lattes.cnpq.br/2508953043452613por
dc.date.accessioned2017-03-27T17:13:56Z-
dc.date.issued2008-03-13-
dc.identifier.citationMagalhães, Gilberto Vilas Boas. Implementação de medições automatizadas de interferências eletromagnéticas. 2008. [105]. dissertação( Mestrado em Engenharia de Telecomunicações) - Instituto Nacional de Telecomunicações, [Santa Rita do Sapucaí] .por
dc.identifier.urihttp://tede.inatel.br:8080/tede/handle/tede/136-
dc.description.resumoA compatibilidade eletromagnética (EMC) é a capacidade de um dispositivo elétrico ou um sistema de operar em seu ambiente eletromagnético sem provocar distúrbio ou ser perturbado. O objetivo deste trabalho é estudar dos ensaios de susceptibilidade eletromagnético e interferência eletromagnética desenvolvendo programas para as medidas de emissão irradiada e conduzida. Um fator predominante em medições de emissão irradiada e conduzida relacionase ao tempo de varredura, com emprego de detectores de quase pico e de nível médio para o sinal a ser usado no analisador de espectros. Utilizou-se como referência o equipamento disponível no laboratório de medições. Normas nacionais e internacionais estabelecem os valores e faixas de freqüência para os ensaios, determinados com emprego de detectores específicos para cada caso. Como a amplitude medida com o detector de pico é sempre maior ou igual à obtida com detectores de quase pico e de nível médio, existe possibilidade de realização dos ensaios. Efetua-se a varredura com detector de pico, que exige um tempo muito menor do que dos outros detectores. Um programa desenvolvido com o LabViewTM compara as medidas com os limites estabelecidos por normas. Caso sejam ultrapassados, realizam-se medições para as freqüências em que o fato ocorrer. Para a emissão conduzida, determinam-se as perturbações nos terminais de energia elétrica, empregando- se uma rede de estabilização de impedância (LISN) como interface com o analisador de espectros. Os ensaios de emissão irradiada são realizados com o equipamento sob análise (EUT) no interior de uma câmara anecóica, a uma distância conhecida da antena. Para se determinar a intensidade de campo elétrico, a antena deve estar calibrada. Isto é verificado a partir das especificações de diversas características, como o ganho, o comprimento efetivo e o fator da antena. Desses valores, o programa efetua a conversão da tensão medida para a intensidade de campo elétrico.por
dc.description.abstractElectromagnetic compatibility (EMC) is the capability of an electrical device or system to operate in its electromagnetic environment, without disturbing or being disturbed by it. The aim of this thesis is to study the electromagnetic susceptibility, and electromagnetic interference experiments, developing software to measure the radiation and conducted emission. A predominant factor for the development programs in measurements of radiated and conducted emission relates with sweep time, applying quasi peak and average detectors for the signal measured through the spectrum analyzer. That equipment was available and used as a reference one. Domestic and international standards show the values and frequency range for the experiment, determined with the detectors, specified for each case. As the level with the peak detector is always greater or equal to the obtained with quasi peak and average detectors, there is a possibility to make experiment. It takes place by using the peak detector, whose sweep time is less than the other type. A developed program using LabViewTM compares the measurements among the specified limit. If exceeding, this value would perform the measurement only for those frequencies. For the conducted emission, it is determined the disturbances at the power supply wires, with the line impedance stabilization network (LISN) connected to the spectrum analyzer. The radiation emissions are performed with the equipment under test inside the anechoic chamber, in a known distance from the antenna. The electric field intensity is determined from antenna data sheet that includes the gain and antenna factor, it must be calibrated. These data are used by programs to convert the measurement level to electric field intensity.eng
dc.description.provenanceSubmitted by Tede Dspace (tede@inatel.br) on 2017-03-27T17:13:56Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) diss. Gilberto.pdf: 1412172 bytes, checksum: ebd309c72c6cd6aa82c2c2603d4b333b (MD5)eng
dc.description.provenanceMade available in DSpace on 2017-03-27T17:13:56Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) diss. Gilberto.pdf: 1412172 bytes, checksum: ebd309c72c6cd6aa82c2c2603d4b333b (MD5) Previous issue date: 2008-03-13eng
dc.formatapplication/pdf*
dc.thumbnail.urlhttp://tede.inatel.br:8080/jspui/retrieve/1157/diss.%20Gilberto.pdf.jpg*
dc.languageporpor
dc.publisherInstituto Nacional de Telecomunicaçõespor
dc.publisher.departmentInstituto Nacional de Telecomunicaçõespor
dc.publisher.countryBrasilpor
dc.publisher.initialsINATELpor
dc.publisher.programMestrado em Engenharia de Telecomunicaçõespor
dc.rightsAcesso Abertopor
dc.rights.urihttp://creativecommons.org/licenses/by-nd/4.0/-
dc.subjectAutomação de medidas; interferência eletromagnética.por
dc.subject.cnpqEngenharia - Telecomunicaçõespor
dc.titleImplementação de medições automatizadas de interferências eletromagnéticaspor
dc.typeDissertaçãopor
Appears in Collections:Mestrado em Engenharia de Telecomunicações

Files in This Item:
File Description SizeFormat 
diss. Gilberto.pdfImplementação de medições automatizadas de interferências eletromagnéticas1.38 MBAdobe PDFThumbnail

Download/Open Preview


This item is licensed under a Creative Commons License Creative Commons